The biocomposite interference screw system is specifically designed for the fixation and stabilization of bone-tendon-bone or soft tissue grafts. Its primary function is to promote appropriate bone growth while undergoing complete resorption.
Ligament reconstruction surgeries, for example, anterior and posterior cruciate ligaments of the knee.
Situations where temporary stability and progressive osteointegration of the graft are required.
Biocomposite material (PLGA + β-TCP). Osteoinductive; promotes bone formation and osteointegration.
Conical, cannulated design. Facilitates insertion and maximizes fixation to bone.
Fully bioabsorbable. Degrades by hydrolysis in 2-4 years without requiring removal.
Speak with our specialists, receive personalized assistance, and optimize your experience in the operating room with a solution designed for precision and confidence.
| MALIBU® - Biocomposite Interference Screws / 0LC-03-0000-B-B | ||
|---|---|---|
| IMPLANTS | ||
| SYSTEM CODE | 0LC-03-0000-B-B | |
| SYSTEM DESCRIPTION | BIOCOMPOSITE IMPLANTS FOR ACL/PCL | |
| REF. | DESCRIPTION | QTY |
| 3787-025 | INTERFERENCE SCREW 7.0 MM X 25 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3787-030 | INTERFERENCE SCREW 7.0 MM X 30 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3788-025 | INTERFERENCE SCREW 8.0 MM X 25 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3788-030 | INTERFERENCE SCREW 8.0 MM X 30 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3789-025 | INTERFERENCE SCREW 9.0 MM X 25 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3789-030 | INTERFERENCE SCREW 9.0 MM X 30 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 3790-030 | INTERFERENCE SCREW 10.0 MM X 30 MM BIOCOMPOSITE (TCP30PLGA) | 2 |
| 1559-000 | SMALL LIGAMENT STAPLE TITANIUM | 1 |
| 1560-000 | MEDIUM LIGAMENT STAPLE TITANIUM | 1 |
| 1561-000 | LARGE LIGAMENT STAPLE TITANIUM | 1 |
| 1581-000 | EXTEND BUTTON LOOP TITANIUM | 1 |
| 1590-000 | ADJUSTABLE BUTTON LOOP | 2 |
| 2071-015 | BUTTON LOOP 15 MM TITANIUM | 1 |
| 2071-020 | BUTTON LOOP 20 MM TITANIUM | 1 |
| 2071-025 | BUTTON LOOP 25 MM TITANIUM | 1 |
| 2071-030 | BUTTON LOOP 30 MM TITANIUM | 1 |
| 2072-000 | BUTTON MINI LOOP 10 MM TITANIUM | 1 |
| ASSOCIATED INSTRUMENTS | ||
| SYSTEM CODE | 0LC-04-0000-0-O | |
| SYSTEM DESCRIPTION | INSTRUMENTS FOR ACL/LCP | |
| REF. | DESCRIPTION | QTY |
| 8991-000 | POSTERIOR CRUCIATE LIGAMENT TIBIAL POSITIONER | 1 |
| 8992-000 | POSTERIOR CRUCIATE LIGAMENT FEMORAL POSITIONER | 1 |
| 8993-000 | ANTERIOR CRUCIATE LIGAMENT TIBIAL POSITIONER, ELBOW TYPE | 1 |
| 8994-000 | ANTERIOR CRUCIATE LIGAMENT TIBIAL POSITIONER | 1 |
| 12339-000 | CANUTO OUT-IN FEMORAL POSITIONER | 1 |
| 12752-000 | CRUCIATE LIGAMENT GUIDE BODY | 1 |
| 12753-000 | CRUCIATE LIGAMENT GUIDE BUSHING 2.5 MM | 1 |
| 12784-000 | METAL HEMI-CANNULA 3.5 MM | 1 |
| 6895-000 | CANNULATED DRILL 6.0 MM | 1 |
| 5620-000 | FEMORAL CANNULATED DRILL 7.0 MM | 1 |
| 5621-000 | FEMORAL CANNULATED DRILL 8.0 MM | 1 |
| 5622-000 | FEMORAL CANNULATED DRILL 9.0 MM | 1 |
| 5623-000 | FEMORAL CANNULATED DRILL 10.0 MM | 1 |
| 6883-000 | CANNULATED DRILL 11.0 MM | 1 |
| 6884-000 | CANNULATED DRILL 12.0 MM | 1 |
| 13023-000 | CANNULATED TIBIAL DRILL 5.0 MM | 1 |
| 13024-000 | CANNULATED TIBIAL DRILL 6.0 MM | 1 |
| 13025-000 | CANNULATED TIBIAL DRILL 7.0 MM | 1 |
| 13026-000 | CANNULATED TIBIAL DRILL 8.0 MM | 1 |
| 13027-000 | CANNULATED TIBIAL DRILL 9.0 MM | 1 |
| 13028-000 | CANNULATED TIBIAL DRILL 10.0 MM | 1 |
| 13029-000 | CANNULATED TIBIAL DRILL 11.0 MM | 1 |
| 6551-000 | BUTTON CANNULATED DRILL BIT FOR LIGAMENT | 1 |
| 5040-000 | SUTURE RETRIEVER HOOK | 1 |
| 2443-000 | STEINMANN PIN 2.4 MM X 230 MM | 2 |
| 6732-000 | NITINOL WIRE FOR INTERFERENCE 1.1 MM | 2 |
| 0319-400 | STEINMANN PIN 2.5 MM 400 MM, STAINLESS STEEL | 2 |
| 0356-440 | TENDON PASSING DRILL 2.5 440 MM WITH CLOSED EYELET | 4 |
| 5624-020 | STRIPPER 5 MM | 1 |
| 5626-020 | STRIPPER 7 MM | 1 |
| 13059-020 | STRIPPER 9 MM | 1 |
| 5105-000 | STAPLE IMPACTOR | 1 |
| 13300-000 | GRAFT GAUGE #3 | 1 |
| 5816-000 | PIN HOLDER | 1 |
| 6201-030 | MALLET #2 | 1 |
| 5655-000 | LARGE STRAIGHT OSTEOTOME | 1 |
| 5657-000 | LARGE CURVED OSTEOTOME | 1 |
| 7658-000 | FRONT SUTURE CUTTER | 1 |
| 5418-020 | TRANSTIBIAL GUIDE 5.0 MM | 1 |
| 5419-020 | TRANSTIBIAL GUIDE 6.0 MM | 1 |
| 5420-020 | TRANSTIBIAL GUIDE 7.0 MM | 1 |
| 6472-020 | TRANSTIBIAL GUIDE, 4.0 MM 30° | 1 |
| 6473-020 | TRANSTIBIAL GUIDE, 6.0 MM 30° | 1 |
| 6475-020 | TRANSTIBIAL GUIDE, 8.0 MM 30° | 1 |
| 5001-000 | TUNNEL GAUGE 130 MM | 1 |
| 6887-020 | CURETTE 6 MM ACL | 1 |
| 6579-000 | CURETTE FOR POSTERIOR LIGAMENT | 1 |
| 6495-000 | POSTERIOR PROTECTOR FOR LIGAMENT | 1 |
| 5619-020 | ANTERIOR LIGAMENT RASP | 1 |
| 7736-000 | INTERFERENCE SCREW TAP 6.5-7.0 MM | 1 |
| 7737-000 | INTERFERENCE SCREW TAP 8.0 MM | 1 |
| 7738-000 | INTERFERENCE SCREW TAP 9.0 MM | 1 |
| 7739-000 | INTERFERENCE SCREW TAP 10.0 MM | 1 |
| 7740-000 | INTERFERENCE SCREW TAP 11.0 MM | 1 |
| 7741-000 | INTERFERENCE SCREW TAP 12.0 MM | 1 |
| 12590-000 | QUICK-CONNECT DILATOR 7 MM | 1 |
| 12591-000 | QUICK-CONNECT DILATOR 8 MM | 1 |
| 12592-000 | QUICK-CONNECT DILATOR 9 MM | 1 |
| 12593-000 | QUICK-CONNECT DILATOR 10 MM | 1 |
| 12594-000 | QUICK-CONNECT DILATOR 11 MM | 1 |
| 12595-000 | QUICK-CONNECT DILATOR 12 MM | 1 |
| 12021-000 | QUICK-CONNECT HANDLE, CRICKET-TYPE | 2 |
| 12022-000 | T-HANDLE FOR DILATORS | 1 |
| 10271-000 | QUICK-CONNECT CANNULATED SCREWDRIVER FOR INTERFERENCE SCREW (TI) | 2 |
| 10272-000 | QUICK-CONNECT CANNULATED SCREWDRIVER FOR INTERFERENCE SCREW (PEEK) | 2 |
| 10273-000 | QUICK-CONNECT CANNULATED SCREWDRIVER FOR MALIBU SCREW | 2 |
| 13074-000 | QUADRICEPS TENDON STRIPPER | 1 |
| OPTIONALS | ||
| REF. | DESCRIPTION | |
| 0LC-04-TABL-0-O | GRAFT PREPARATION TABLE 2 | |
| 1605-000 | ADJUSTABLE UP IN BELT LOOP BUTTON + SUB TWIST ANCHOR | |
| 3699-020 | INTERFERENCE SCREW 6.0 MM X 20 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3699-025 | INTERFERENCE SCREW 6.0 MM X 25 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3699-030 | INTERFERENCE SCREW 6.0 MM X 30 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3787-020 | INTERFERENCE SCREW 7.0 MM X 20 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3788-020 | INTERFERENCE SCREW 8.0 MM X 20 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3789-020 | INTERFERENCE SCREW 9.0 MM X 20 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3790-020 | INTERFERENCE SCREW 10.0 MM X 20 MM BIOCOMPOSITE (TCP30PLGA) | |
| 3790-025 | INTERFERENCE SCREW 10.0 MM X 25 MM BIOCOMPOSITE (TCP30PLGA) | |
| PM-2022-20 / PM-2022-30 / PM-2022-53 / PM-2022-82 | ||